Publikationen

U-236/U-238 and Pu-240/Pu-239 isotopic ratios in small (2 L) sea and river water samples

Autor(en)
R. Eigl, M. Srncik, P. Steier, Gabriele Wallner
Abstrakt

Accelerator Mass Spectrometry (AMS) and alpha spectrometry were used to determine uranium (236U, 238U, 234U) and plutonium isotopes (239Pu, 240Pu) in sea and river water samples. Plutonium was separated by Dowex® 1 × 8 resin and UTEVA® resin was used for uranium purification. The measured 236U/238U isotopic ratios for surface water from the Atlantic Ocean, the Pacific Ocean and the Black Sea were in the order of 10−9, while values for river water were in the order of 10−8.

These contaminations may be attributed to global fallout. A sample of

the reference material IAEA-443, collected from the Irish Sea, showed,

in accordance to the reference value, a ratio that was 103 times higher due to effluents from the reprocessing plant at Sellafield. These results underline the good suitability of 236U/238U

as a tracer for hydrology and oceanography, and show that relatively

small water samples are sufficient for the determination of 236U

by AMS, which is not the case for plutonium with present techniques.

The plutonium concentrations in our water samples could only be measured

with large uncertainties and were in the order of 10−3 mBq/L (with the exception of the Irish Sea sample).

Organisation(en)
Institut für Anorganische Chemie, Isotopenphysik
Journal
Journal of Environmental Radioactivity
Band
116
Seiten
54-58
Anzahl der Seiten
5
ISSN
0265-931X
DOI
https://doi.org/10.1016/j.jenvrad.2012.09.013
Publikationsdatum
02-2013
Peer-reviewed
Ja
ÖFOS 2012
1030 Physik, Astronomie, 103031 Strahlenschutz, 104020 Radiochemie, 103005 Atomphysik
Schlagwörter
Link zum Portal
https://ucrisportal.univie.ac.at/de/publications/e2ecdd57-88aa-41e7-9e64-ee346faed26e