Sorption of uranium on freshly prepared hydrous titanium oxide and its utilization in determination of U-236 using accelerator mass spectrometry

Autor(en)
I. Spendlikova, Mojmir Nemec, P. Steier, G. Keceli
Abstrakt

The determination of

236U with accelerator mass spectrometry (AMS) requires efficient separation methods with high concentration factors. The article proposes an alternative method of uranium separation from aqueous solutions to commonly used iron co-precipitation. This “homogeneous precipitation” is based on unique properties of fresh hydrous titanium oxide, prepared by hydrolysis of its organic precursor—tetra-n-butylorthotitanate—directly in the aqueous sample solution. Besides high uranium uptake, the results shows very promising properties of this uranium-titanium oxide precipitate for

236U-AMS measurements providing up to 4 times higher negative ion yield comparing with common uranium oxide matrix.

Organisation(en)
Isotopenphysik
Externe Organisation(en)
Czech Technical University in Prague (CTU), Istanbul University
Journal
Journal of Radioanalytical and Nuclear Chemistry
Band
311
Seiten
447-453
Anzahl der Seiten
7
ISSN
0236-5731
DOI
https://doi.org/10.1007/s10967-016-5013-0
Publikationsdatum
01-2017
Peer-reviewed
Ja
ÖFOS 2012
103014 Kernphysik, 104020 Radiochemie
Schlagwörter
ASJC Scopus Sachgebiete
Public Health, Environmental and Occupational Health, Analytical Chemistry, Pollution, Radiology Nuclear Medicine and imaging, Spectroscopy, Health, Toxicology and Mutagenesis, Nuclear Energy and Engineering
Link zum Portal
https://ucris.univie.ac.at/portal/de/publications/sorption-of-uranium-on-freshly-prepared-hydrous-titanium-oxide-and-its-utilization-in-determination-of-u236-using-accelerator-mass-spectrometry(f5fd6b53-6745-4ab9-a047-5739e293fe4b).html