Characterization and improvement of thin natural diamond detectors for spectrometry of heavy ions below 1 MeV/amu

Autor(en)
Peter Steier, Vitaly Kh Liechtenstein, Denia Djokic, Robin Golser, Anton Wallner, A.G. Alexeev, V.S. Khrunov, Walter Kutschera
Abstrakt

In our previous paper [V.Kh. Liechtenstein, N.V. Eremin, R. Golser, W. Kutschera, A.A. Paskhalov, A. Priller, P. Steier, Ch. Vockenhuber, S. Winkler, Nucl. Instr. and Meth. A 521 (2004) 2031, first results on the evaluation of thin natural diamond-based detectors (NDDs) as an energy spectrometer for heavy ions in the energy range below 1 MeV/amu were presented. Although results were promising, the energy resolution of the detector was limited by an unexpected high-energy loss in the "dead layer" of the entrance window. In this paper, we report a significant improvement in the spectrometric properties of two highly selected and carefully treated NDDs with electrical contacts made of carbon and gold films as thin as about 10 and 20 mu g/cm(2), respectively, instead of much thicker aluminum contacts used before. In particular, for the NDD with thin carbon contact an energy resolution of 7.6% for Au-197-ions at 20.6 MeV was obtained. The energy cut-off of the detectors was reduced to 0.9 and 1.5 MeV for carbon and gold contact, respectively. The measured data on energy cut-off for different projectiles are compared with calculations, which yields an estimate of the thickness of the dead layers. Long-term irradiation runs proved stable spectroscopic performance of the detectors, in spite of the inherent "pumping" effects and imperfections of pulse height distributions. Our data suggest that NDD-based spectrometers might outperform other detector types in applications where very fast detectors with high radiation tolerance are required.

Organisation(en)
Isotopenphysik
Externe Organisation(en)
Russian Research Centre Kurchatov Institute, Troitsk Institute for Innovation and Fusion Research, Institute for Physical and Technical Problems, Universität Wien
Journal
Nuclear Instruments & Methods in Physics Research. Section A. Accelerators, Spectrometers, Detectors, and Associated Equipment
Band
590
Seiten
221-226
Anzahl der Seiten
6
ISSN
0168-9002
DOI
https://doi.org/10.1016/j.nima.2008.02.038
Publikationsdatum
2008
Peer-reviewed
Ja
ÖFOS 2012
1030 Physik, Astronomie, 103014 Kernphysik
Link zum Portal